FX 3300 LabAir IV
Air Permeability Tester
FX 3300 LabAir IV
Demo Video:
Measures the air permeability of all kinds of flat materials as well as foam cubes. TEXTEST’s most successful instrument.
Special Features
-
Wide measuring range of 1-10,000 l/m²/s at 20 cm² test area (0.1-1,300 ft³/ft²/min at 38 cm²).
-
Wide test pressure range of 20-2,000 Pa
-
For filter media: Determination of the pressure drop at a given air velocity.
-
Optional FX 3300-PNA Pneumatic Clamping Assembly for test samples with a high percentage of side air.
-
Automatic control of the test pressure.
-
Fast and simple sample clamping.
-
Touch screen display for digital and graphic display of the test result.
-
Quiet and mobile instrument, perfectly suitable for use in the laboratory and in the production area.
-
Automatic cleaning function of the orifice provides for stable test results.
-
Data ports: RS 232 and UBS. Ethernet and optional WLAN for direct network access.
-
Optional integrated software for evaluation and storage of the test results in XML format.
-
Optional integrated strip printer for printing of a test report.
-
Can be connected to a PC with the Evaluation Program L 5110 LABODATA III.
-
Works in accordance with all major test standards.
-
Calibratable.
Parameters
Measuring range :
0.4 … 750 cm³/cm²/s bei 5 cm²
1 … 10‘000 mm/s (l/m²/s) bei 20 cm²
0.6 … 6‘000 l/dm²/min bei 20 cm²
0.002 … 20 dm³/s bei 25 cm²
0.1 … 1‘300 ft³/ft²/min bei 38 cm²
0.05 … 700 cm³/cm²/s bei 38 cm²
0.03 … 400 m³/m²/min bei 38 cm²
2 … 24‘000 m³/m²/h bei 38 cm²
0.1 … 1‘600 l/dm²/min bei 100 cm²
20 … 2‘500 Pa bei 1 … 10‘000 mm/s bei 20 cm²
Units of measure :
mm/s, l/m²/s, l/dm²/min, ft³/ft²/min, cm³/cm²/s, m³/m²/min, m³/m²/h, dm³/s,Pa (pressure drop), mks rayl und cgs rayl (air flow resistance)
Measurement Accuracy :
Better than ± 3 % of the displayed value
Test pressure:
Test areas:
Data ports:
User interface:
20 … 2,500 Pa (expandable to 5,000 Pa)
5, 20, 25, 38 and 100 cm² (others on request)
-
RS 232 C, asynchronous, bi-directional
-
USB 2.0 for USB flash drive
-
Ethernet and Wi-Fi as options
Touch display
Power requirements:
-
195 … 260 VAC, 50/60 Hz, max. 1,100 W
-
85 … 130 VAC, 50/60 Hz, max. 1,100 W
Compressed air requirements:
5 … 8 bar (only required for cleaning function, the instrument can be operated without compressed air)
Test Standards
-
AFNOR G07-111
-
ASTM D 737
-
ASTM D 3’574
-
BS 5’636
-
EDANA 140.1
-
DIN 53’887
-
EDANA 140.1
-
EN ISO 7’231
-
EN ISO 9’237
-
EN 14683, Annex C
-
JIS L 1’096-A
-
TAPPI T 251
-
WSP 70.1